Category 6

Category 6

The Construction Products Regulation (CPR) is a “common technical language” that proposes the standardized assessment of the fire performance of building materials throughout the European region.

LS Simple provides CPR rated cables from category 5e to 6A in different types of structure to enable our customers to fulfill their requirments.

Category 6

  • U/UTP CAT.6 LSZH DCA

    CABLE CONSTRUCTION Conductor: The conductors shall be solid, annealed and bare copper with a diameter of AWG23~24 and minimum acceptable diameter shall be 0.485mm Insulation: Each conductor shall be insulated with solid high density polyethylene or FEP(only CMP cable). The insulation shall be uniform and shall not have any defects. Sheath: The flame retardant PVC or LSZH(Low Smoke […]
    Read more
  • U/UTP CAT.6 LSZH CCA

    CABLE CONSTRUCTION Conductor: The conductors shall be solid, annealed and bare copper with a diameter of AWG24 and AWG23 Insulation: Each conductor shall be insulated with solid high density polyethylene. The insulation shall be uniform and shall not have any defects. The diameter over the insulation shall be maximum 1.22mm. Sheath: The flame retardant LSZH(Low Smoke Zero Halogen) compound colored grey or other colors shall be applied over the cable core. The sheath shall be uniform and shall not have any defects. ELECTRICAL PERFORMANCE Characteristics Units Specification DC Resistance Ω/100m ≤ 9.38 DC Resistance Unbalance % ≤ 5.00 Capacitance Unbalance (Pair to Ground) pF/km (800~1000Hz) ≤ 330 Insulation Resistance MΩ-100m ≥ 500 Dielectric […]
    Read more
  • U/UTP CAT.6 LSZH B2CA

    CABLE CONSTRUCTION Conductor: The conductors shall be solid, annealed and bare copper with a diameter of AWG24 and AWG23. Insulation: Each conductor shall be insulated with solid high density polyethylene. The insulation shall be uniform and shall not have any defects. The diameter over the insulation shall be maximum 1.22mm. Sheath: The flame retardant LSZH(Low Smoke Zero Halogen) compound colored grey or other colors shall be applied over the cable core. The sheath shall be uniform and shall not have any defects. ELECTRICAL PERFORMANCE Characteristics Units Specification DC Resistance Ω/100m ≤ 9.38 DC Resistance Unbalance % ≤ 5.00 Capacitance Unbalance (Pair to Ground) pF/km (800~1000Hz) ≤ 330 Insulation Resistance MΩ-100m ≥ 500 Dielectric […]
    Read more
  • U/UTP CAT.6 23AWG NON-FILLER LSZH B2CA

    CABLE CONSTRUCTION Conductor: The conductors shall be solid, annealed and bare copper with a diameter of AWG23 Insulation: Each conductor shall be insulated with solid high density polyethylene. The insulation shall be uniform and shall not have any defects. The diameter over the insulation shall be maximum 1.22mm. Sheath: The flame retardant LSZH(Low Smoke Zero Halogen) compound colored grey or other colors shall be applied over the cable core. The sheath shall be uniform and shall not have any defects. ELECTRICAL PERFORMANCE Characteristics Units Specification DC Resistance Ω/100m ≤ 9.38 DC Resistance Unbalance % ≤ 5.00 Capacitance Unbalance (Pair to Ground) pF/km (800~1000Hz) ≤ 330 Insulation Resistance MΩ-100m ≥ 500 Dielectric Strength DC kV/sec 2.5 / 2 Impedance (Characteristic mean) Ω 100 ± 15%  (1 ≤ […]
    Read more
  • F/UTP CAT.6 PVC DOUBLE SHEATH

    CABLE CONSTRUCTION Conductor: The conductors shall be solid , annealed and bare copper with a diameter of AWG24 and minimum acceptable diameter shall be 0.485mm. Insulation: Each conductor shall be insulated with solid high density polyethylene. The insulation shall be uniform and shall not have any defects. The diameter over the insulation shall be maximum 1.22mm. Screen: The […]
    Read more
  • U/UTP CAT.6 PVC ECA

    CABLE CONSTRUCTION Conductor: The conductors shall be solid, annealed and bare copper with a diameter of AWG23~24 and minimum acceptable diameter shall be 0.485mm. Inuslation: Each conductor shall be insulated with solid high density polyethylene or FEP(only CMP cable). The insulation shall be uniform and shall not have any defects. Sheath: The flame retardant PVC or LSZH(Low Smoke […]
    Read more
  • F/UTP CAT.6 LSZH UL SPEC

    CABLE CONSTRUCTION Conductor: The conductors shall be solid , annealed and bare copper with a diameter of AWG23~24 and minimum acceptable diameter shall be 0.485mm. Inuslation: Each conductor shall be insulated with solid high density polyethylene. The insulation shall be uniform and shall not have any defects. The diameter over the insulation shall be maximum 1.22mm. Screen: The […]
    Read more

Scroll to Top