- CABLE CONSTRUCTION
- Conductor: The conductors shall be solid, annealed and bare copper with a diameter of AWG23~24 and minimum acceptable diameter shall be 0.485mm
Insulation: Each conductor shall be insulated with solid high density polyethylene or FEP(only CMP cable). The insulation shall be uniform and shall not have any defects.
Sheath: The flame retardant PVC or LSZH(Low Smoke Zero Halogen) compound colored grey or other colors shall be applied over the cable core. The sheath shall be uniform and shall not have any defects.
- ELECTRICAL PERFORMANCE
-
Characteristics Units Specification DC Resistance Ω/100m ≤ 9.38 DC Resistance Unbalance % ≤ 5.00 Capacitance Unbalance
(Pair to Ground)pF/km
(800~1000Hz)≤ 330 Insulation Resistance MΩ-100m ≥ 500 Dielectric Strength DC kV/sec 2.5 / 2 Impedance (Characteristic mean)
Ω 100 ± 15% (1 ≤ f ≤ 250MHz) Return Loss dB/100m ≥ 20 + 5 * log(freq) , 1 ≤ f < 10MHz
≥ 25 , 10 ≤ f < 20MHz
≥ 25 – 7 * log(freq/20) , 20 ≤ f ≤ 250MHzAttenuation
(Insertion Loss)dB/100m ≤ 1.808*√(freq) + 0.017*(freq) + 0.20/√(freq)
, 1 ~ 250 MHzNEXT Loss dB/100m ≥ 44.3 – 15*log(freq/100) , 1 ~ 250MHz Power sum NEXT Loss dB/100m ≥ 42.3 – 15*log(freq/100) , 1 ~ 250MHz ELFEXT Loss dB/100m ≥ 27.8 – 20*log(freq/100) , 1 ~ 250MHz Power sum ELFEXT Loss dB/100m ≥ 24.8 – 20*log(freq/100) , 1 ~ 250MHz Propagation Delay dB/100m ≤ 534 + 36 / √(Freq) , 1 ~ 250MHz Propagation Delay Skew dB/100m ≤ 45
- CPR COMPLIANT
- The LSZH(CMX) product comply with CPR reaction to fire : Dca-s2-d2-a1