- DESCRIPTION
- . Coaxial cable for comnnection of devices intended for television reception like a satellite broadcasting of 75 ohms charateristics impedence or related devices
- LISTS
- . 5C-HFBT
. 7C-HFBT
. 10C-HFBT
- CABLE CONSTRUCTION
- 5C-HFBT series
ITEM UNIT 5C-HFBT 5C-HFBT-A Inner conductor Material – Copper CCS Diameter mm 1.20 ± 0.03 1.02 ± 0.05 Insulation Material – Foamed PE Foamed PE Thickness mm 1.90 ± 0.05 1.73 ± 0.05 Diameter mm 5.00 ± 0.1 4.57 ± 0.1 Color – Natural Natural Outer
conductor1st shield Material – Al/mylar tape Al/mylar tape Thickness mm 0.042 ± 0.003 0.051 ± 0.003 2nd shield Material – Tin-coated Annealed Copper (TA) Aluminum wire (A) Individual wire diameter mm 0.120 ± 0.005 0.150 ± 0.01 Construction Number of wires per carrier x number of carriers 6 x 16 3 x 16 Lay length mm 46 ± 5 32 ± 5 3rd shield Material – Al/mylar tape Al/mylar tape Thickness mm 0.025 ± 0.003 0.025 ± 0.003 Jacket Material – PVC PVC Color – Black Black Thickness mm 0.90 ± 0.1 0.83 ± 0.1 Diameter mm 7.40 ± 0.5 7.06 ± 0.5 7C-HFBT series
ITEM UNIT SPECIFICATION Inner conductor Material – CCS Cu Diameter mm 1.63 ± 0.1 1.80 ± 0.1 Insulation Material – Foamed PE Foamed PE Thickness mm 2.74 ± 0.1 2.75 ± 0.1 Diameter mm 7.11 ± 0.2 7.30 ± 0.2 Color – Natural Natural Outer
Conductor1st shield Material – Al/mylar tape Al/mylar tape Thickness mm 0.025 ± 0.003 0.042 ± 0.003 2nd shield Material – Aluminum wire Tinned copper wire Individual wire diameter mm 0.156 0.140 Construction Number of wires per carrier x number of carriers 6 x 16 5 x 16 Lay length mm 42 ± 5 40 ± 5 3rd shield Material – Al/mylar tape Al/mylar tape Thickness mm 0.025 ± 0.003 0.025 ± 0.003 Jacket Material – PVC PVC Thickness mm 1.0 ± 0.125 1.0 ± 0.125 Diameter mm 10.0 ± 0.5 10.0 ± 0.5 10C-HFBT series
ITEM UNIT 10C-HFBT 10C-HFBT-CCA Inner conductor Material – Copper CCA
(Copper Clad Aluminum)Diameter mm 2.40 ± 0.03 2.40 ± 0.15 Insulation Material – Foamed PE Foamed PE Thickness mm 3.50 ± 0.1 3.50 ± 0.1 Diameter mm 9.40 ± 0.2 9.40 ± 0.2 Color – Natural Natural Outer
Conductor1st shield Material – Al/mylar tape Al/mylar tape Thickness mm 0.042 ± 0.003 0.042 ± 0.003 2nd shield Material – Tin-coated Annealed Copper Aluminum Individual wire
diametermm 0.160 0.160 Construction Number of wires per carrier x
number of carriers7 x 16 7 x 16 Lay length mm 40 ± 5 40 ± 5 3rd shield Material – Al/mylar tape Al/mylar tape Thickness mm 0.025 ± 0.003 0.025 ± 0.003 Jacket Material – PVC PVC Color – Black Black Thickness mm 1.0 ± 0.2 1.0 ± 0.2 Diameter mm 12.3 ± 0.5 12.3 ± 0.5
- TECHNICAL DETAILS
- Electrical Characteristics
– Refer to data sheetPhysical Characteristics
ITEM UNIT SPECIFICATION REMARK Jacket
(before heat-aged)Tensile Strength kgf/mm2 ≥ 1.02 According to
KS C 3004 / clause 19Elongation % ≥ 200 Jacket
(after heat-aged)Tensile Strength % ≥ 80 According to
KS C 3004 / clause 20Elongation % ≥ 80 Jacket Shrinkage (100℃/4h) % ≤ 10 According to
KS C 3004 / clause 24Cold Bend Test (-20℃/1h) – No visible crack According to
KS C 3004 / clause 23Cold Impact Test (-10℃/2.5min.) – No visible crack According to
KS C 3004 / clause 25Conductor Discoloration – No corrosion/discoloration on
inner & outer conductorAccording to
KS C 3002 / clause 3Min. Bending Radius – 6 x Cable Diameter