HFBT

DESCRIPTION
. Coaxial cable for comnnection of devices intended for television reception like a satellite broadcasting of 75 ohms charateristics impedence or related devices
LISTS
. 5C-HFBT
. 7C-HFBT
. 10C-HFBT
CABLE CONSTRUCTION
5C-HFBT series

ITEM UNIT 5C-HFBT 5C-HFBT-A
Inner conductor Material Copper CCS
Diameter mm 1.20 ± 0.03 1.02 ± 0.05
Insulation Material Foamed PE Foamed PE
Thickness mm 1.90 ± 0.05 1.73 ± 0.05
Diameter mm 5.00 ± 0.1 4.57 ± 0.1
Color Natural Natural
Outer
conductor
1st shield Material Al/mylar tape Al/mylar tape
Thickness mm 0.042 ± 0.003 0.051 ± 0.003
2nd shield Material Tin-coated Annealed Copper (TA) Aluminum wire (A)
Individual wire diameter mm 0.120 ± 0.005 0.150 ± 0.01
Construction Number of wires per carrier x number of carriers 6 x 16 3 x 16
Lay length mm 46 ± 5 32 ± 5
3rd shield Material Al/mylar tape Al/mylar tape
Thickness mm 0.025 ± 0.003 0.025 ± 0.003
Jacket Material PVC PVC
Color Black Black
Thickness mm 0.90 ± 0.1 0.83 ± 0.1
Diameter mm 7.40 ± 0.5 7.06 ± 0.5

7C-HFBT series

ITEM UNIT SPECIFICATION
Inner conductor Material CCS Cu
Diameter mm 1.63 ± 0.1 1.80 ± 0.1
Insulation Material Foamed PE Foamed PE
Thickness mm 2.74 ± 0.1 2.75 ± 0.1
Diameter mm 7.11 ± 0.2 7.30 ± 0.2
Color Natural Natural
Outer
Conductor
1st shield Material Al/mylar tape Al/mylar tape
Thickness mm 0.025 ± 0.003 0.042 ± 0.003
2nd shield Material Aluminum wire Tinned copper wire
Individual wire diameter mm 0.156 0.140
Construction Number of wires per carrier x number of carriers 6 x 16 5 x 16
Lay length mm 42 ± 5 40 ± 5
3rd shield Material Al/mylar tape Al/mylar tape
Thickness mm 0.025 ± 0.003 0.025 ± 0.003
Jacket Material PVC PVC
Thickness mm 1.0 ± 0.125 1.0 ± 0.125
Diameter mm 10.0 ± 0.5 10.0 ± 0.5

10C-HFBT series

ITEM UNIT 10C-HFBT 10C-HFBT-CCA
Inner conductor Material Copper CCA
(Copper Clad Aluminum)
Diameter mm 2.40 ± 0.03 2.40 ± 0.15
Insulation Material Foamed PE Foamed PE
Thickness mm 3.50 ± 0.1 3.50 ± 0.1
Diameter mm 9.40 ± 0.2 9.40 ± 0.2
Color Natural Natural
Outer
Conductor
1st shield Material Al/mylar tape Al/mylar tape
Thickness mm 0.042 ± 0.003 0.042 ± 0.003
2nd shield Material Tin-coated Annealed Copper Aluminum
Individual wire
diameter
mm 0.160 0.160
Construction Number of wires per carrier x
number of carriers
7 x 16 7 x 16
Lay length mm 40 ± 5 40 ± 5
3rd shield Material Al/mylar tape Al/mylar tape
Thickness mm 0.025 ± 0.003 0.025 ± 0.003
Jacket Material PVC PVC
Color Black Black
Thickness mm 1.0 ± 0.2 1.0 ± 0.2
Diameter mm 12.3 ± 0.5 12.3 ± 0.5
TECHNICAL DETAILS
Electrical Characteristics
– Refer to data sheet

Physical Characteristics

ITEM UNIT SPECIFICATION REMARK
Jacket
(before heat-aged)
Tensile Strength kgf/mm2 ≥ 1.02 According to
KS C 3004 / clause 19
Elongation % ≥ 200
Jacket
(after heat-aged)
Tensile Strength % ≥ 80 According to
KS C 3004 / clause 20
Elongation % ≥ 80
Jacket Shrinkage (100℃/4h) % ≤ 10 According to
KS C 3004 / clause 24
Cold Bend Test (-20℃/1h) No visible crack According to
KS C 3004 / clause 23
Cold Impact Test (-10℃/2.5min.) No visible crack According to
KS C 3004 / clause 25
Conductor Discoloration No corrosion/discoloration on
inner & outer conductor
According to
KS C 3002 / clause 3
Min. Bending Radius 6 x Cable Diameter
Scroll to Top