U/UTP CAT.5E 24AWG LSZH DCA

CABLE CONSTRUCTION
Conductor: The conductors shall be solid , annealed and bare copper with a diameter of AWG24 and minimum acceptable diameter shall be 0.485mm.
Insulation: Each conductor shall be insulated with solid high density polyethylene or FEP(only CMP cable).
Sheath: The flame retardant PVC or LSZH (Low Smoke Zero Halogen) compound colored grey or other colors shall be applied over the cable core.
ELECTRICAL PERFORMANCE
Characteristics Units Specification
DC Resistance Ω/100m ≤ 9.38
DC Resistance Unbalance % ≤ 5.00
Mutual Capacitance nF/100m ≤ 5.60
Capacitance Unbalance
(Pair to Ground)
pF/km ≤ 330
Insulation Resistance MΩ-100m ≥ 500
Dielectric Strength DC kV/sec 2.5 / 2
Impedance

(Characteristic mean)

Ω 100 ± 15% (1 ≤ f ≤ 100MHz)
Return Loss dB/100m ≥ 20 + 5 * log(freq)        1 ≤ f  < 10MHz
≥ 25                                  10 ≤ f < 20MHz
≥ 25 – 7 * log(freq/20)   20 ≤ f ≤ 100MHz
Attenuation
(Insertion Loss)
dB/100m ≤ 1.967*√(freq) + 0.023*(freq) + 0.05/√(freq)
1 ~ 100 MHz
NEXT Loss dB/100m ≥ 35.3 – 15*log(freq/100) , 1 < f ≤ 100MHz
Power sum NEXT Loss dB/100m ≥ 32.3 – 15*log(freq/100) , 1 < f ≤ 100MHz
ELFEXT Loss dB/100m ≥ 23.8 – 20*log(freq/100) , 1 ~ 100MHz
Power sum ELFEXT Loss dB/100m ≥ 20.8 – 20*log(freq/100) , 1 ~ 100MHz
Propagation Delay dB/100m ≤ 534 + 36 / √ (Freq) , 1 ~ 100MHz
Propagation Delay Skew dB/100m ≤ 45
CPR COMPLIANT
– The LSZH(CMX) product comply with CPR reaction to fire : Dca-s2-d2-a1