- CABLE CONSTRUCTION
- Conductor: The conductors shall be solid , annealed and bare copper with a diameter of AWG24 and minimum acceptable diameter shall be 0.485mm.
Insulation: Each conductor shall be insulated with solid high density polyethylene or FEP(only CMP cable).
Sheath: The flame retardant PVC or LSZH (Low Smoke Zero Halogen) compound colored grey or other colors shall be applied over the cable core.
- ELECTRICAL PERFORMANCE
-
Characteristics Units Specification DC Resistance Ω/100m ≤ 9.38 DC Resistance Unbalance % ≤ 5.00 Mutual Capacitance nF/100m ≤ 5.60 Capacitance Unbalance
(Pair to Ground)pF/km ≤ 330 Insulation Resistance MΩ-100m ≥ 500 Dielectric Strength DC kV/sec 2.5 / 2 Impedance (Characteristic mean)
Ω 100 ± 15% (1 ≤ f ≤ 100MHz) Return Loss dB/100m ≥ 20 + 5 * log(freq) 1 ≤ f < 10MHz
≥ 25 10 ≤ f < 20MHz
≥ 25 – 7 * log(freq/20) 20 ≤ f ≤ 100MHzAttenuation
(Insertion Loss)dB/100m ≤ 1.967*√(freq) + 0.023*(freq) + 0.05/√(freq)
1 ~ 100 MHzNEXT Loss dB/100m ≥ 35.3 – 15*log(freq/100) , 1 < f ≤ 100MHz Power sum NEXT Loss dB/100m ≥ 32.3 – 15*log(freq/100) , 1 < f ≤ 100MHz ELFEXT Loss dB/100m ≥ 23.8 – 20*log(freq/100) , 1 ~ 100MHz Power sum ELFEXT Loss dB/100m ≥ 20.8 – 20*log(freq/100) , 1 ~ 100MHz Propagation Delay dB/100m ≤ 534 + 36 / √ (Freq) , 1 ~ 100MHz Propagation Delay Skew dB/100m ≤ 45
- CPR COMPLIANT
- – The LSZH(CMX) product comply with CPR reaction to fire : Dca-s2-d2-a1