The Construction Products Regulation (CPR) is a “common technical language” that proposes the standardized assessment of the fire performance of building materials throughout the European region.
LS Simple provides CPR rated cables from category 5e to 6A in different types of structure to enable our customers to fulfill their requirments.
Category 6A
U/UTP CAT.6A 1ST GENERATION LSZH DCA
CABLE CONSTRUCTION Conductor: The conductors shall be solid, annealed and bare copper with a diameter of AWG23 and minimum acceptable diameter shall be 0.546mm. Insulation: Each conductor shall be insulated with solid high density polyethylene. The Insulation shall be uniform and shall not have any defects. The diameter over the insulation shall be maximum 1.22mm. Sheath: The flame retardant PVC or LSZH(Low Smoke Zero Halogen) compound colored grey or other colors shall be applied over the cable core. ELECTRICAL PERFORMANCE Characteristics Units Specification DC Resistance Ω/100m ≤ 9.38 DC Resistance Unbalance % ≤ 4.00 Capacitance Unbalance (Pair to Ground) pF/km (800~1000Hz) ≤ 330 Insulation Resistance MΩ-100m ≥ 100 Dielectric Strength DC kV/sec 2.5 / 2 Impedance (Characteristic mean) Ω 100 ± 5% at […]Read moreU/UTP CAT.6A SUPER SLIM LSZH DCA
CABLE CONSTRUCTION Conductor:Â The conductors shall be solid, annealed and bare copper with a diameter of AWG23 and minimum acceptable diameter shall be 0.546mm. Insulation:Â Each conductor shall be insulated with HDPE or FEP (In case of Plenum grade). The insulation shall be uniform and shall not have any defects. The diameter over the insulation shall be […]Read moreU/UTP CAT.6A DOUBLE SHEATH LSZH CCA
CABLE CONSTRUCTION Conductor:Â The conductors shall be solid, annealed and bare copper with a diameter of AWG23. Insulation:Â Each conductor shall be insulated with HDPE. The insulation shall be uniform and shall not have any defects. The diameter over the insulation shall be maximum 1.22mm. Non-continuous Shield:Â The non-continuous aluminum tape shall be applied over the core wrapping […]Read moreU/UTP CAT.6A SINGLE SHEATH LSZH CCA
CABLE CONSTRUCTION Conductor: The conductors shall be solid, annealed and bare copper with a diameter of AWG23. Insulation: Each conductor shall be insulated with HDPE. The insulation shall be uniform and shall not have any defects. The diameter over the insulation shall be maximum 1.22mm. Non-continuous Shield: The non-continuous aluminum tape shall be applied over the core wrapping to increase alien crosstalk performances. Sheath: The flame retardant LSZH(Low Smoke Zero Halogen) compound colored grey or other colors shall be applied over the cable core. ELECTRICAL PERFORMANCE Characteristics Units Specification DC Resistance Ω/100m ≤ 9.38 DC Resistance Unbalance % ≤ 5.00 Capacitance Unbalance (Pair to Ground) pF/km ≤ 330 Insulation Resistance MΩ-100m ≥ 500 Dielectric Strength DC kV/sec 2.5 / 2 Impedance (Characteristic mean) Ω 100 ± 15% (1 […]Read moreU/UTP CAT.6A SUPER SLIM LSZH(CM) DCA
CABLE CONSTRUCTION Conductor:Â The conductors shall be solid, annealed and bare copper with a diameter of AWG23 and minimum acceptable diameter shall be 0.546mm. Insulation:Â Each conductor shall be insulated with HDPE or FEP (In case of Plenum grade). The insulation shall be uniform and shall not have any defects. The diameter over the insulation shall be […]Read moreU/UTP CAT.6A ULTRA SUPER SLIM LSZH ECA
CABLE CONSTRUCTION Conductor:Â The conductors shall be solid, annealed and bare copper with a diameter of AWG26 Insulation:Â Each conductor shall be insulated with solid high density polyethylene. The insulation shall be uniform and shall not have any defects. Sheath:Â The flame retardant PVC or LSZH(Low Smoke Zero Halogen) compound colored grey or other colors shall be applied […]Read moreF/UTP CAT.6A LSZH DCA
CABLE CONSTRUCTION Conductor:Â The conductors shall be solid , annealed and bare copper with a diameter of AWG23 and minimum acceptable diameter shall be 0.546mm. Insulation:Â Each conductor shall be insulated with solid high density polyethylene. and FEP for CMP cable. The insulation shall be uniform and shall not have any defects. The diameter over the insulation […]Read more